IBM X335 server Specifications:

IBM X335 server Processor:

Intel Pentium 4 microprocessor

Minimum: One

Maximum: Two

512KB Level 2 cache

400MHz front side bus (FSB)

IBM X335 server Memory

Error correcting code (ECC), double-data rate (DDR) SDRAM, registered DIMMs

Minimum: 512MB

Maximum: 4GB (enabled for 8GB)

Four slots, interleaved

IBM X335 server Drives standard

Diskette: 1.44MB

CD-ROM: IDE

IBM X335 server Hard disk drives

Slim line drives, hot-swap SCSI or non-hot-swap IDE (drive capacity and speed vary with model)

Maximum: Two

IBM X335 server Expansion slots

One full length adapter slot supports up to 100MHz/64-bit PCI-X adapters (bus A)

One half length adapter slot supports up to 100MHz/64-bit PCI-X adapters (bus B) or 33MHz 32-bit PCI adapters (bus C)

Supports 3.3V or universal adapters only

IBM X335 server Power supply

One 331W t (115-230V AC)

IBM X335 server Video

ATI RageXL video controller integrated on system board

Compatible with SVGA

8MB SDRAM video memory

IBM X335 server Size

Height 43mm (1.69 inch)

Depth: 660mm (25.98 inch)

Width: 440mm (17.32 inch)

Weight: approximately 12.7kg (28 lb) when fully configured

IBM X335 server Integrated functions

Integrated system management processor (ISMP) with one ISM (RS-485) connector

One SCSI controller with RAID1 capability

Two Broadcom 10/100/1000 Ethernet controllers with Wake on LAN support and Alert Standard Format (ASF)

Three Universal Serial Bus (USB) ports

One serial port

Two Cable Chaining Technology (C2T) ports (one In, one Out)

Acoustical noise emissions

Declared sound power, idling: 6.5 bels

Declared sound power, operating: 6.5 bels

IBM X335 server Environment

Air temperature

Server on: 10° to 35°Celsius (50.0° to 95.0°Fahrenheit). Altitude: 0 to 914m (2998.7 ft)

Server on: 10° to 32°Celsius (50.0° to 89.6°Fahrenheit). Altitude: 914m (2998.7 ft) to 2133m (6998.0 ft.)

Server off: 10° to 43°elsius (50.0° to 109.4°Fahrenheit). Maximum altitude: 2133m (6998.0 ft)

Humidity

Server on: 8% to 80%

Server off: 8% to 80%

IBM X335 server Airflow rates

Minimum: 31.4 CFM

Maximum: 39.2 CFM

IBM X335 server Heat output

Approximate heat output in British thermal units (Btu) per hour:

Minimum configuration: 375 Btu (110W)

Maximum configuration: 1195 Btu (350W)

Electrical input

Sine-wave input (50-60Hz) required

Input voltage low range:

Minimum: 100V AC

Maximum: 127V AC

IBM X335 server Input voltage high range:

Minimum: 200V AC

Maximum: 240V AC

Input kilovolt-amperes (kVA), approximately

Minimum: 0.110 kVA 